Simple. Comfort 3. Thermostat Instructions | e. How. Remove the fuse or switch off the appropriate circuit breaker to turn off power to the heating and cooling system. Remove the cover of your old thermostat by inserting a screwdriver into the slots on the sides of the thermostat (check your owner's manual on removing your thermostat if this method will not work for your specific model). This will expose its wires. Using the enclosed wire labels, label the wires and then remove them from their terminals.
Page 1. INSTALLATION INSTRUCTIONS E2009 Lennox Industries Inc. Dallas, Texas, USA ® Elite Series CBX32M Units WARNING AIR HANDLER Improper installation, adjustment. View and Download Lennox XP21 Series installation instructions manual online. Dave Signature Collection System. XP21 Series Heat Pump pdf manual download.
Unscrew the old thermostat's base from the wall with a screwdriver. Insert the screwdriver into the slots at the sides of the Simple.
Read 10 reviews of LENNOX central air conditioners written from May 2014 to Feb 2015 or write your own review. SimpleComfort 3000 Thermostat Instructions. The SimpleComfort 3000 from ICM Controls is a seven-day programmable electronic thermostat. Suited for residential and.
Comfort 3. 00. 0 thermostat and twist it to remove the cover. Place the thermostat base against the wall where your old thermostat was.
504,626M 03/10 Page 1 2002 Lennox Industries Inc. Dallas, Texas, USA RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Do not store or use gasoline or other. Page 1 02/13 507067-01 2013 Lennox Industries Inc. Dallas, Texas, USA AIR FLOW UPFLOW AIR FLOW AIR FLOW HORIZONTAL LEFT HORIZONTAL RIGHT INSTALLATION INSTRUCTIONS. Manuals, parts lists, wiring diagrams for HVAC equipment: Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air.
The wires should feed through the wire opening in the thermostat's base. Mark the placement of the mounting holes on the wall with a pencil. Remove the base from the wall.
![Lennox Elite Series Thermostat Installation Instructions Lennox Elite Series Thermostat Installation Instructions](http://www.hvacpartsshop.com/ProductImages/miscellaneous/59M03_300.jpg)
Use the drill and 3/1. Then, with the hammer, tap the supplied anchors into the mounting holes. With the anchors in place on the wall, align the base of the thermostat with the anchors and place the control wires through the wire opening. Use the screws included with your package to mount the thermostat base to the anchors. Insert the stripped, labeled wires into their matching wire terminals. Do not allow exposed wires to touch other wires. Tighten the screws on the terminal block with a screwdriver, then seal the hole for the wires behind the thermostat with nonflammable insulation or putty.
Set the "Gas/Electric" switch to match your system: "Gas" for oil or gas systems, "Electric" for heat pumps or electric heat systems. Insert two AA batteries into the thermostat, then snap the thermostat cover into place over the mounted base. Reactivate the power by replacing the fuse or switching the appropriate circuit breaker back to the "On" position.
LENNOX XP2. 1 SERIES INSTALLATION INSTRUCTIONS MANUAL Pdf Download. This unit must be installed with an See the icomfort Touch thermostat Quick Start Guide ® approved indoor air handler or coil. See the Lennox XP2.
Engineering Handbook for approved indoor component wiring connections. Unit Dimensions −− Inches (mm) 3. DISCHARGE AIR (9. ELECTRICAL INLET (HIGH VOLTAGE) 3. AND −0. 36) 4. 7 (1. AND −0. 60) 4−1/2 (1.
SUCTION LINE INLET ELECTRICAL INLET (CONTROL WIRING − LOW VOLTAGE) LIQUID LINE SOLAR MODULE 1. INLET WIRING.. LIQUID VALVE AND GAUGE PORT CRANKCASE HEATER (HR1) TRUE SUCTION LINE (BELLY BAND) PORT CRANKCASE HEATER THERMOSTAT (S4. LIQUID LINE BI−FLOW HIGH PRESSURE FILTER DRIER SWITCH (S4) LOW PRESSURE SWITCH (S8. Figure 1. Plumbing, Switches and Sensor Components Page 3 XP2. SERIES.. Assembled outdoor unit.
See the Lennox Service and Application Notes #C−0. Bag assembly which includes the following: Page 4 5. STEM CAP TO OUTDOOR UNIT NOTE A label with specific torque requirements may be affixed to the stem cap. If the label is present, use the specified torque. Figure 2. Angle and Ball Service Valves Page 5 XP2. SERIES.. Recovering Refrigerant from Existing System DISCONNECT POWER CONNECT MANIFOLD GAUGE SET Disconnect all power to the existing outdoor unit at the disconnect Connect a gauge set, clean recovery cylinder and a recovery switch or main fuse box/breaker panel. Use the instruction provided with the recovery machine to make the connections.
If it is necessary to extend to a window see the provided illustration in figure 5, further, consider a different type of field−fabricated detail A. Page 7 XP2. 1 SERIES.. DETAIL A Outside Unit Placement DETAIL B Slab Mounting at Ground Level Install unit away from windows.
Install unit level or, if on a slope, maintain slope tolerance of two (2) degrees (or two inches per five feet [5. While handling or stowing the panels, consider any weather conditions, especially windy conditions, that INLET AIR may cause panels to be blown around and battered. INLET AIR Figure 6. Rooftop Application and Wind Barrier Page 9 XP2. SERIES.. REMOVING AND INSTALLING PANELS Panel shown slightly rotated to allow top tab to exit (or enter) top slot for removing (or installing) panel.
REMOVE 4 SCREWS TO WARNING REMOVE PANEL FOR LOUVERED PANEL REMOVAL ACCESSING COMPRESSOR Remove the louvered panels as follows: AND CONTROLS. This section provides information on installation or replacement of existing line set. If new or replacement line To obtain the correct information from Lennox, be sure to set is not being installed then proceed to Brazing communicate the following information: Connections on page 1. Line Set Isolation The following illustrations are examples of proper refrigerant line set isolation: REFRIGERANT LINE SET INSTALLING REFRIGERANT LINE SET TRANSITION VERTICAL RUNS (NEW CONSTRUCTION SHOWN) FROM VERTICAL TO HORIZONTAL NOTE Insulate liquid line when it is routed through areas where the surrounding ambient temperature could become higher than the temperature of the liquid line or when pressure drop is equal to or greater ANCHORED HEAVY NYLON.. Wash hands with soap and water after handling brazing plosion, that could result in property alloys and flux.
Page 1. 3 XP2. 1 SERIES.. CAP AND CORE REMOVAL PIPING PANEL REMOVAL AND PREPARING LINE Remove service cap and core from both the suction / vapor and liquid line service ports. Remove piping panel for easier access to service valves. Cut ends SERVICE PORT CAP of the refrigerant lines square (free from nicks or dents) and debur the ends. After all connections have been brazed, disconnect manifold gauge set from service ports. Apply additional water saturated cloths to both services valves to cool piping.
Once piping is cool, remove all water saturated cloths. Refer to the unit installation instructions for the next step in preparing the unit. Figure 1. 0. Brazing Procedures (Continued) Page 1.
XP2. 1 SERIES.. Flushing Line Set and Indoor Coil The following procedure should not be performed on a system which contain contaminants (i. TYPICAL EXISTING FIXED ORIFICE TYPICAL EXISTING EXPANSION VALVE REMOVAL REMOVAL PROCEDURE (UNCASED PROCEDURE (UNCASED COIL SHOWN) COIL SHOWN) STUB END TWO PIECE PATCH PLATE LIQUID LINE.. Installing Indoor Expansion Valve This outdoor unit is designed for use in systems that use check expansion valve metering device. See the Lennox XP2. Engineering Handbook for approved check expansion valve kit match−ups and application information.
The check expansion valve unit can be installed internal or external to the indoor coil. In applications where an uncased coil is being installed in a field−provided plenum, install the check expansion valve in a manner that will provide access for field servicing.. Pa). and line set must be flushed prior to installation. Take care to empty all existing traps.
Polyol ester (POE) oils are used in Lennox units charged with HFC−4. A WARNING refrigerant. Residual mineral oil can act as an insulator, preventing proper heat transfer.
Reinstall service valve cores by removing manifold hose from service valve. Quickly install cores with core tool while maintaining a positive system pressure. Replace stem caps and secure finger tight, then tighten an additional one−sixth (1/6) of a turn as illustrated. Figure 1. 4. Evacuating System Page 1. XP2. 1 SERIES.. temperatures and pressures present during operation of IMPORTANT an air conditioning system.
Non−condensables and water suction combine with refrigerant to produce substances Use a thermocouple or thermistor electronic vacuum that corrode copper piping and compressor parts. Use an instrument Electrical capable of accurately measuring down to 5. HIGH VOLTAGE ELECTRICAL INLET CONDUIT HOLE CONTACTOR (HIGH VOLTAGE) WATERTIGHT CONDUIT FITTING WIRING ENTRY POINTS WATERTIGHT FLEXIBLE CONDUIT TO SERVICE DISCONNECT BOX ELECTRICAL INLET (CONTROL WIRING LOW VOLTAGE).
USE BUSHING PROVIDED IN BAG ASSEMBLY HERE. ACCESS VIEW Page 2. XP2. 1 SERIES.. Figure 1. Typical XP2. 1 Wiring Page 2. Earlier produce units will have a default factory setting (jumper *NO JUMPER present) for 4. F. Later produce units will have no jumper by default present on E4. Figure 1. 6. Heat Pump Control Connections, Jumper Settings and LED Locations Page 2.
XP2. 1 SERIES.. Table 3. Heat Pump Control (A1. Jumper and Terminal Descriptions Control ID Label Description PSC Fan 2. VAC output connection for outdoor fan.
PSC Fan 2. 40. VAC input connection for outdoor fan. VAC output for defrost auxiliary heat output. Thermostat service light connection.
VAC thermostat input/output for second stage operation of the unit. Harmony IIIt zoning system applications.
This will slow the indoor blower motor to the lowest speed setting. See furnace installation instruction or engineering handbook for lowest fan speed information. Figure 1. 7. Comfort. Sense® 7. 00. 0 Series Thermostat Air Hander/Two−Stage Heat Pump Page 2. XP2. 1 SERIES.. INTEGRATED FURNACE CONTROL INDOOR (A9.
THERMOSTAT (S1) HEAT PUMP On−board link CONTROL (A1. Low voltage thermostat wiring 1. Thermostat T terminals are used for outdoor sensor input. Use for thermostat’s outdoor temperature display (optional). R to L connection is required for this model when using the Comfort.
Sense 7. 00. 0 −.. BConnect the manifold gauge set’s low pressure side to the true suction port. CConnect the manifold gauge set’s high pressure side to the liquid line service port. DPosition temperature sensor on liquid line near liquid line service port. Figure 1. 9. Gauge Set Connections Page 2. XP2. 1 SERIES.. ADDING OR REMOVING REFRIGERANT Temperature rise between the return air and supply air This system uses HFC−4.
A refrigerant which operates at temperatures at the indoor coil blower unit, much higher pressures than HCFC−2. The pre−installed liquid line filter drier is approved for use with HFC−4. A Measuring voltage supplied to the unit, only. If refrigerant is added or removed, repeat steps 5 through 6 to verify charge. Disconnect gauge set and re−install both the liquid and suction service valve caps. Figure 2. 2. Using HFC−4. A Subcooling Method High Stage (High Capacity) Page 2.
XP2. 1 SERIES.. Air Handler / Coil Match ups and Targeted Subcooling Values Listed below are the targeted subcooling and charging values for approved indoor unit air handler / coil match ups. This information is also listed on the unit charging sticker located on the access panel. Indicates amount of charge required in additional to charge shown on unit nameplate. High Stage Cooling Operation 6. Page 3. 1 XP2. 1 SERIES..
Table 9 HFC−4. 10. A Temperature (°F) − Pressure (Psig) °F Psig °F Psig °F Psig °F Psig °F Psig °F Psig °F Psig °F Psig 1. Defrost calibration and operation (see figure 2.
Heating and cooling operation will Defrost test (see figure 2. Page 3. 3 XP2. 1 SERIES.. If the jumper is not connected to one of the temperature High Discharge Line Temperature Sensor (RT2.
E4. 8 (4. 0, 4. 5, 5. F), the second stage See table 1.
The high discharge line lock−in feature is inactive. Factory default is no jumper temperature sensor (location shown in figure 1 monitors present. E4. 7 E4. 7 pins*. Calibration Attempted (Unit Running in Heat Mode) Calibration Figure 2. Defrost Calibration Sequence of Operations Page 3. XP2. 1 SERIES.. MULTI−FUNCTION TEST PINS (E3.
Placing the jumper on the field test pins (E3. Clear short cycle lockout Clear five−strike fault lockout Cycle the unit in and out of defrost mode Manually place the unit in defrost mode to clear the coil When Y1 is energized and 2. V power is being applied to the heat pump control (A1. TEST pins for 2 to 5 seconds. CONTACTOR ENERGIZED LED ALERT CODE / OR NORMAL PRESSURE MODERATE CLOSED OPERATION SWITCH (S8. ALERT 4. 10 DISPLAYED SERVICE REQUIRED WAITING FOR PRESSURE OPEN CLOSED SWITCH TO CLOSE Figure 2. Low Pressure Switch (S8.
Sequence of Operation Page 3.